Question 1

Which of the following is/are benefits of commissioning?

Options:

A.

Ensures a system is designed to operate as intended

B.

Ensures a system is installed to operate as intended

C.

Ensures staff know how to operate a system as intended

D.

Ensures staff know how to maintain a system as intended

E.

All of the above

Question 2

You can buy air compressor A for $15,000 or air compressor B for $6,000. Compressor A will cost $10,000 per year to operate. Compressor B will cost $11,500 per year to operate. If both air compressors have a 10-year life and your required return on investment is 12%, which air compressor has the lowest total life-cycle cost?

Options:

A.

Compressor A

B.

Compressor B

C.

Both air compressors have the same life-cycle cost

Question 3

A facility replaces a natural gas heating system rated at 10,000 kJ/h and 80% efficiency with an electric heat pump rated at 10,000 kJ/h and a coefficient of performance (COP) of 2.3. Will this project also reduce the annual energy utilization index (EUI) for the facility?

Options:

A.

Yes

B.

No

Question 4

Which heat recovery device listed below can be used to preheat boiler make-up water using the heat energy from skimming blowdown?

Options:

A.

Shell and tube heat exchanger

B.

Regenerative recouperator

C.

Desiccant heat wheel

D.

Heat pipe

Question 5

A fully-loaded heat pump unit delivers 36-kW thermal heating with a power draw of 12-kW electric. What is the coefficient of performance (COP) at full load?

Options:

A.

2.0

B.

3.0

C.

4.0

D.

5.0

E.

6.0

Question 6

What is the main cause of low power factor?

Options:

A.

Harmonics

B.

Fluorescent lighting

C.

Solar flares

D.

Computers and electronic equipment

E.

Low-load induction motors

Question 7

If the temperature difference across an external wall is 20°C and the heat flow across the wall is 2.5 Watts/m², calculate the insulation value of the wall (including inside and outside air films)?

Options:

A.

R = 4 m²-°C/W

B.

R = 6 m²-°C/W

C.

R = 8 m²-°C/W

D.

R = 10 m²-°C/W

E.

R = 12 m²-°C/W

Question 8

A 75-kW induction motor operates at 80% partial load and 88% efficiency. A new high-efficiency 75-kW motor can be installed that will operate at 95% efficiency (also at 80% partial load). What is the reduction in electric power demand?

Options:

A.

1 kW

B.

2 kW

C.

4 kW

D.

5 kW

E.

8 kW

Question 9

An energy-saving project costs $540,000. The project will have maintenance costs of $25,000 per year. The energy savings from the project are $160,000 per year. What is the simple payback of the project?

Options:

A.

2.0 years

B.

3.0 years

C.

4.0 years

D.

5.0 years

Question 10

A cooling tower delivers 29°C water to a central chilled water plant. The cooling tower is capable of delivering water to the chilled-water plant with a 6°C approach temperature to the ambient wet bulb temperature. Using this information, what type of control strategy would you recommend be added to the cooling tower operation to save additional energy?

Options:

A.

Chilled-water temperature reset

B.

Condenser-water temperature reset

C.

Chiller demand limiting

D.

Static-pressure reset

Question 11

The temperature in an unconditioned mechanical room is found to typically be around 23°C warmer than ambient air. If the air intake of an air compressor located in the mechanical room is routed through a nearby wall so that ambient air is fed directly to the air compressor's intake, what impact can be expected on the air compressor's energy requirement?

Options:

A.

Increase energy use by 7.6%

B.

Increase energy use by 3.8%

C.

No measureable change in energy use

D.

Decrease energy use by 3.8%

E.

Decrease energy use by 7.6%

Question 12

Infiltration (inward air leakage) in a building is dependent on several factors. Which of the following is least likely to affect or influence infiltration in a building?

Options:

A.

Outside air wind speed

B.

Outside air temperature

C.

Building height

D.

Fuel type used for heating and cooling

E.

Poor or missing weatherstripping

Question 13

What is the definition of lamp life for a fluorescent lamp?

Options:

A.

The time at which lamps begin to fail

B.

The time at which 50% of a large sample of lamps have failed

C.

The time at which 70% of a large sample of lamps have failed

D.

The time at which lumen output has reduced by 50%

E.

The time at which lumen output has reduced to 70% of the initial light output

Question 14

Which motor parameter is the most difficult to measure with precision?

Options:

A.

Operating (rotating) speed

B.

Output power capacity

C.

Input power

D.

Alternating current (AC) frequency

E.

Operating load factor

Question 15

An air-conditioning unit delivers 10,000 kJ/h (thermal cooling). The equipment uses single-phase electrical power at 220-volt and 5.25 amps with a power factor of 100%. Calculate the coefficient of performance (COP).

Options:

A.

2.4

B.

3.2

C.

6.2

D.

13.2

E.

16.1

Question 16

A hot-water boiler has a cut-in set point of 65°C on the hot water supply temperature and a differential set point of 10°C. What is the hot-water supply temperature that causes the boiler to turn off?

Options:

A.

55°C

B.

65°C

C.

75°C

D.

It depends on the return water temperature

Question 17

A compressed air system has a total volume of 247,500 liters. During a 30-minute break in production (air compressor system turned off and no production demand for compressed air), the system pressure drops from 7 bar, gauge (700 kPa, gauge) to 5 bar, gauge (500 kPa, gauge). Calculate the leakage rate in the compressed air system.

Options:

A.

8,250 liters/minute

B.

16,500 liters/minute

C.

22,750 liters/minute

D.

32,000 liters/minute

E.

48,250 liters/minute

Question 18

In a warehouse, lights are mounted 4 meters above the floor. This provides an average light level of 150 lux. To increase the light level without installing more lights or higher Wattage lights, you lower the light fixtures with pendants so that the lights are located 3.25 meters above the floor. Calculate the new average light level on the floor.

Options:

A.

150 lux

B.

166 lux

C.

176 lux

D.

227 lux

E.

276 lux

Question 19

If outside air has a temperature of 30°C dry bulb and 20°C wet bulb, what is the dew point temperature?

Options:

A.

15°C

B.

20°C

C.

25°C

D.

30°C

Question 20

What is the purpose of monitoring energy consumption?

SELECT THE CORRECT ANSWER

Options:

A.

To establish a basis of management control

B.

To establish when and why there is a deviation in energy consumption patterns

C.

To support analysis of energy information

D.

All of the above

Question 21

An air-conditioning system at full load is rated at 70-kW (thermal cooling) and has a coefficient of performance (COP) of 4.1. What is the electrical load at full load?

Options:

A.

17.1 kW

B.

23.3 kW

C.

35.0 kW

D.

46.7 kW

E.

70.0 kW

Question 22

The International Performance Measurement and Verification Protocol (IPMVP) has how many categories (method options) to determine the performance of an energy- or water-consuming system?

Options:

A.

2 Options

B.

3 Options

C.

4 Options

D.

5 Options

E.

6 Options

Question 23

A 25-kW motor, at full load, drives a centrifugal fan that produces 160,000 liters per second (l/s) of ventilation air. If the fan speed is reduced to a flow rate of 150,000 l/s, what is the new load on the motor?

Options:

A.

15.2 kW

B.

20.6 kW

C.

24.2 kW

D.

25.0 kW

E.

30.3 kW

Question 24

A steam trap with a 6-mm orifice in an 0.8-MPa steam system has failed open. The steam system is pressurized8.760 hours/yr. The steam cost is $15.00 /GJ. Using thetable below, what is the annualcost of the vented steam through the failed steam trap? ignore any condensate return issues.

[The question from the previous image, which was about calculating the annual cost of heat loss through a wall, but had a discrepancy between the calculated cost and the provided answer choices]

Options:

A.

$5,000/yr

B.

$10,000/yr

C.

$20,000/yr

D.

$30,000/yr

E.

$40,000/yr

Question 25

Which type of single-phase alternating-current motor has the highest efficiency?

Options:

A.

Electronic-commutated motor

B.

Shaded-pole motor

C.

Permanent split-capacitor motor

Question 26

Using the lumen method, calculate the number of luminaires (fixtures) required to light a room to 200 lux. Each luminaire has 2 fluorescent lamps, 3,000 lumens per lamp. The room is 20 meters by 30 meters. The total light loss factor (LLF) is 0.70 and the luminaire coefficient of utilization (CU) is 0.80.

Options:

A.

12 luminaires

B.

24 luminaires

C.

36 luminaires

D.

48 luminaires

E.

60 luminaires

Question 27

Exhaust gases from an industrial furnace flow through a heat-recovery steam generator, which generates medium-pressure steam. This steam is used in a steam turbine to generate shaft power driving a fan. Which type of combined heat and power (CHP) cycle does this process describe?

Options:

A.

Topping cycle

B.

Bottoming cycle

C.

Combined cycle

D.

This cycle is not a combined heat and power system

Question 28

Which pump system listed below is most likely the best application for converting to variable-speed drive?

Options:

A.

Pump system with parallel rotary lobe pumps in a rebar quenching application with a static head of 80m

B.

Pump system with on-off control transferring liquid vertically from a low tank to a higher tank

C.

Pump system with bypass control transferring liquid from an intake dam to a process in production

D.

Pump system with throttle fully open circulating liquid in a closed loop cooling system

Question 29

Which is the best application for variable-speed drives?

Options:

A.

Reciprocating air compressor

B.

Waste-water sewer lift pump

C.

Centrifugal fan motor in a variable-air volume air-conditioning system

D.

Centrifugal fan motor in a multi-zone air conditioning system

Question 30

What is the Energy Use index (EUl) for a 4,000 m2 building that uses the following amountsof energy each year?

Options:

A.

403,311 kJ/m²-yr

B.

625,600 kJ/m²-yr

C.

855,250 kJ/m²-yr

D.

1,612,000 kJ/m²-yr

E.

3,220,800 kg/m²-yr

Question 31

An office building is illuminated with T8 fluorescent lamps. Which of the following is the best schedule for group relamping (total replacement of all the T8 fluorescent lamps in the building)?

Options:

A.

When you reach 70% of the rated lamp life

B.

Every 4 years

C.

When 25% of the lamps have failed

D.

When 20% of the ballasts have failed

E.

When the building owner changes

Question 32

Which of the following controls can optimize the operation of lighting systems?

Options:

A.

Dimming ballasts

B.

Photocells

C.

Occupancy sensors

D.

Timer

E.

All of the above

Question 33

Which of the following statements best describe Demand Control Ventilation (DVC) in Building Automation Systems?

Options:

A.

It satisfies indoor ventilation rates by preconditioning outdoor air with the exhaust air to decrease energy cost during cold, warm, or humid weather

B.

It's a prescriptive procedure in which outdoor air intake rates are calculated based on the energy cost method that compares a proposed building design to a base annual energy cost design

C.

It's a building standard for enclosed spaces in which biological, chemical, and physical contaminants are considered to meet thermal comfort requirements

D.

It's an active evaluation of outdoor and indoor space conditions to determine the amount of thermal, mechanical and natural conditioning that is required

Question 34

A 50-Hz alternating current (AC) induction motor has 3 pole pairs (6 poles). What is the synchronous speed of the motor?

Options:

A.

600 rpm

B.

750 rpm

C.

1,000 rpm

D.

1,500 rpm

Question 35

Air is heated from 10°C (dry bulb temperature) and 80% relative humidity to 32°C (dry bulb temperature). What is the new relative humidity?

Options:

A.

20%

B.

30%

C.

40%

D.

60%

E.

80%

Question 36

According to ISO 50001. when performing internal audits on the energy management system in an organization the internal auditor should do which of the following?

SELECT THE CORRECT ANSWER

Options:

A.

Focus on the areas of significant energy use

B.

Review the written procedures related to the area under audit

C.

Assess actual activities as practiced against what the written procedures state

D.

Look for opportunities for energy improvement and to minimize bureaucracy inthe energy management system

E.

All of the above

Question 37

A facility owner is considering installing a new chiller. The installed project cost will be $300,000. The annual savings from the energy-saving project will be $45,000 for the 20-year life of the chiller. If an energy-service company requires a minimum 20% return on investment (pre-tax), will the energy-service company agree to finance this project?

Options:

A.

Yes

B.

No

Question 38

Which of the following best describes a dead band in controls?

Options:

A.

A range around a set point with no change in state even though there is a change in sensor input

B.

A system which changes the output of a controller based on how fast a variable is moving from or to a set point

C.

The delay in response of a system to a controlled change

D.

A value that has been assigned to a controlled variable

E.

The difference between a sensor variable and its set point

Question 39

Calculate the monthly electric bill for a customer that used 400 kW and 75,000 kwh during one month. Use the following declining block structure for a monthly bill:

SELECT THE CORRECT ANSWER

Options:

A.

$3,280

B.

$4, 580

C.

$7,850

D.

$9,660

E.

$12,500