New Year Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70special

HP HPE0-S60 Delta - HPE Compute Solutions Exam Practice Test

Page: 1 / 8
Total 79 questions

Delta - HPE Compute Solutions Questions and Answers

Testing Engine

  • Product Type: Testing Engine
$37.5  $124.99

PDF Study Guide

  • Product Type: PDF Study Guide
$33  $109.99
Question 1

Refer to the exhibit.

Which statement about this logical interconnect group is true?

Options:

A.

The master modules are located in the interconnect bays 2 and 5

B.

For the given downlink speed, the maximum number of frames is reached

C.

Both master modules are located in the same HPE Synergy frame

D.

To use interconnect bay set 3, all compute nodes must be half-height

Question 2

Which compute node parameters are captured within server hardware type?

Options:

A.

Number of the CPUs

B.

installed operating system

C.

Mezzanine card configuration

D.

Size of the memory Installed

Question 3

Your customer plans to deploy VMware ESXi 7. 0 U2, and they are looking for a hardware platform that will allow them to use up to 16 CPU sockets

Which HPE compute system meets the customer requirements?

Options:

A.

HPE ProLiant DL580 Gen10

B.

HPE ProLiant OL380 Gen 10 Plus

C.

HPE Synergy 480 Gen10 Plus

D.

HPE Superdome Flex system

Question 4

Which statement about an HPE Oneview support dump is true?

Options:

A.

Appliance support dump by default contains a logical enclosure support dump

B.

Support dump is a binary file that can be opened only in a dedicated application

C.

Support dump can be created if HPE Virtual Connect modules are installed in the frame

D.

Preview support dump is available only when creating an appliance support dump

Question 5

Your customer plans to deploy VMware vSAN using D3940 Storage Modules.

Which statement about this solution is true?

Options:

A.

The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.

B.

To use the storage controller that will access D3940 storage modules, a second CPU must be installed.

C.

For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.

D.

All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured

Question 6

Your customer plans to manage HPE Primera using HPE Oneview

Which storage management tasks can be completed using HPE OneView for this environment?

Options:

A.

CPG management

B.

Volume provisioning

C.

Cache management

D.

Replication setup

Question 7

Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames

How will this change impact the customer environment?

Options:

A.

The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.

B.

The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.

C.

The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.

D.

The customer can add a new logical enclosure to an existing setup once all required licenses are addedtoHPE OneView and associated with the new frames.

Question 8

After HPE Superdome Flex deployment and nPar setup, you need to verify health status of HPE Superdome Flex components.

Put the steps on the left into the coned order on the right to perform this task.

Options:

Question 9

Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol

What must be done to complete this task?

Options:

A.

Enable FC primary and secondary boot on the modules through the HPE OneView interface

B.

FC connectivity on the modules should be enabled through the service console by disabling FCoE.

C.

Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules

D.

Enter both modules into a maintenance mode, then enable FC connectivity through CLI

Question 10

Refer to the exhibit.

Which statement about this logical JBOD is true?

Options:

A.

This logical JBOD can be connected to multiple systems to formulate a snared datastore.

B.

After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created

C.

After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done

D.

This logical JBOD can be presented to the compute nodes in a different frame.

Question 11

As a result of the troubleshooting process, you recommend replacing, HPE Synergy Composer modules which HPE Synergy Composer 2

Why would you recommend this change?

Options:

A.

HPE Composer 1 running HPE OneView 5 2 or later can support only 12 frames within a single management nog

B.

HPE Composer 2 can support more than the maximum 21 frames that are supported with HPE Composer 1 and HPE OneView.

C.

HPE Composer 2 provides access to 105 interface that can be used for full management of HPE Composer 2 remotely

D.

HPE Composer 1 cannot support remote frames, which doubles the configuration and management procedures effort

Question 12

Put the steps of the HPE infosight flow in the correct order.

Options:

Question 13

Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives

The customer requested the following components:

- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules

- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy

- An appropriate number of vSAN Standard licenses for each compute node

- One HPE O3940 Storage Module with 40 SSDs - All required cables and options

Which statement about this request is true?

Options:

A.

vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses

B.

vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN

C.

One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM

D.

20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.

Question 14

Which statement about a new HPE SimpliVity deployment is true?

Options:

A.

New HPE SimpliVity deployments gives customer flexible choice of hypervisor

B.

A new HPE SimpliVity node can be a member of multiple dusters

C.

AM new HPE SimpliVity models are software optimized

D.

All new HPE SimpliVity models are based on mid CPUs

Question 15

Your customer has a logical enclosure configured using a angle HPE Synergy frame with the following configuration

- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy

- two HPE Synergy Virtual Connect SE 32Gb FC Modules -12 HPE Synergy 480 Gen10 Plus compute nodes with appropriate mezzanine cards

They plan to add a new HPE Synergy frame to an existing logical enclosure with the following configuration

- two HPE Synergy Virtual Connect SE 32Gb FC Modules

- two HPE Synergy 20Gb interconnect Link Modules

- Eight HPE Synergy 480 Gen 10 Plus compute nodes with appropriate mezzanine cards

Which statement about the planned configuration change is true?

Options:

A.

Four compute modules must be moved to the second frame to balance the configuration

B.

The two HPE Synergy 20Gb interconnect Link Modules must be replace with the 50Gb option

C.

A license for an extended logical enclosure must be added to HPE OneView through GUI

D.

The HPE Synergy virtual Connect SE 32Gb FC Modules from both frames should be stacked

Question 16

You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group

What should you check to fix the issue?

Options:

A.

if both FiexNICs are configured with the same speed

B.

If the logical enclosure is built on at least three HPE Synergy frames

C.

if both FiexNICs are connected to different networks

D.

if the logical enclosure is configured with redundant master modules

Question 17

Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast broadcast and destination lookup failure (OLF) packets?

Options:

A.

Pause flood protection

B.

Loop protection

C.

LLDP tagging

D.

Storm control

Question 18

Your customer added a new Ethernet network in HPE Oneview mat is used to manage their HPE Synergy platform.

When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.

What must be done to fix this issue?

Options:

A.

Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached.

B.

To make this network available to use in the server profile, the customer must enable the Smart Link feature within network definition.

C.

The newly created network must be added to the uplink set within the LIG, and Logical interconnect configuration must be updated from the LIG.

D.

Check within the server profile which server hardware is used and perform the Refresh operation on this compute node to get the latest adapter information.

Question 19

You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support Which interconnects are required to support this connection? (Select two.)

Options:

A.

HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy

B.

HPE Virtual Connect SE 16Gb FC Module for HPE Synergy

C.

HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

D.

HPE Virtual Connect SE 32Gb FC Module for HPE Synergy

E.

Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy

F.

Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy

Question 20

Which statement about HPE Apollo 2000 Gen10 Plus platform is true?

Options:

A.

It is equipped with HPE Persistent memory by default

B.

It can support a single processor only and up to 4 per chassis

C.

It is fully managed using HPE OneView including all connections

D.

It offers servers with AMD EPYC and Intel Xeon Scalable CPUs

Question 21

Match HPE Superdome Flex system with its specific feature.

Options:

Question 22

A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?

Options:

A.

Brocade 32GB Fibre Channel Switch Module for HPE Synergy

B.

HPE virtual Connect SE 32 Gb FC Module for Synergy

C.

HPE Virtual Connect SE 100 Gb F32 Module tor Synergy

D.

HPE Synergy 12 Gb SAS Connection Module

Question 23

Which statement about manual orchestration during the firmware update is true?

Options:

A.

It is supported only for logical enclosures with at least three frames

B.

It provides an ability to select and update one side of the Interconnect topology at a time

C.

It provides the ability to install an older firmware version than currently Installed In the interconnect

D.

It allows all the interconnect modules to be activated manually at the same time.

Page: 1 / 8
Total 79 questions