Which of the following advantages does the UPS5000-A have compared with the NXP, 9395, and Galaxy 7000? (Multiple Choice)
Which of the following statements is correct about the UPS5000-S at lowloads? (Multiple Choice)
The THDV of the UPS5000-A at full linear loads is ().
The UPS5000-A features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-A?
The output power factor of the UPS5000-A-400/500K is (), which can be applicable to new IT loads and greatly improve the loading capacity.
By default, how many PDUs are configured for one cabinet of the FusionModule2000? ( )
What is the maximum number of U cabinets used by the FusionModule2000 with a built-in UPS (N+l power architecture)? ()
Battery strings of different brands and the same capacity can be used in parallel.
The maximum capacity of a single-racked UPS5000-E (50 kVA power module) is 300 kVA.
Which of the following conditions shall be considered whencalculating the UPS rated inputcurrent?
(Multiple Choice)
The UPS2000-G supports low voltage disconnection. Which of the following is not a function of low voltage disconnection? ()
Which of the following Eaton products is similar to the UPS5000-A 30-120 kVA?
UPS spare parts cannot be configured with Unistar SCT.
The DC cable voltage drop must be within ( ).
Which of the following types does the UPS5000-A belong to?
Electric cables are determined on actual project requirements during UPS configuration.
For the 6-kVA UPS2000-G, a 1+1 parallel system requires () DB15 parallel cables to ensure that each UPS is connected by at least two parallel cables and to enhance the parallel system reliability.
Which of the following statements is incorrect about the configuration principle? (Multiple Choice)
The rated loading capacity of a 2+1 parallel system is a maximum of () times the rated loading capacity of a single UPS.
What is the maximum capacity of the UPS5000-E power module?
The model of the UPS2000-G-6KRTL is ( ).
The input power factor (full load) of the UPS5000A is (), which can efficiently reduce the pollution to the power grid and save the preceding power distribution investment.
The UPS5000-E has good scalability, supporting a maximum of () UPSs to be used in parallel.
Which of the following statements are correct? (Multiple Choice)
The UPS5000-A features industry-leading reliability. Which of the following statements is correct about the UPS5000-A reliability design? (Multiple Choice)
Multiple input/output systems can meet the requirements in customers' power grid application scenarios. What input/output systems does the 10-kVA UPS2000-G support? (Multiple Choice)
The built-in SNMP and ModBus card of the UPS5000-A reduce management investment costs for clients.
Which of the following parallel system does the UPS5000-A support? (Multiple Choice)
The optional components and features in the typical configuration solution of the FusionModule800 include ().
The UPS5000-S efficiency is ().
According to related standards and regulations, the AC cable voltage drop must be within 3%. You are advised to control the AC cable voltage drop within () when designing the UPS system.
The height of the UPS2000-G battery pack is ( ).
Which of the following statements are correct about the UPS5000-A (30-120 kVA) reliability? (Multiple Choice)