Question 1

For Halon 1211 hand-hose-line systems, all hoses for high-pressure systems must be tested at __ psi

Options:

A.

600

B.

900

C.

1,500

D.

2,500

Question 2

What is the maximum number of students permitted in a classroom that measures 20 ft. x 30 ft., and which contains four fixed 4 ft. x 8 ft. tables?

Options:

A.

12

B.

24

C.

30

D.

40

Question 3

How long should the fire prevention bureau maintain fire inspection records on a commercial structure?

Options:

A.

For the life of the building.

B.

A maximum of five years.

C.

Until the building is renovated or has a change of occupancy.

D.

At least one year or until the next fire inspection, whichever is later.

Question 4

Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?

Options:

A.

They become a public record.

B.

They are time-consuming to complete and file.

C.

They may not address all of the code violations which may be encountered.

D.

They may serve as a basis for legal appeal against the code official's actions.

Question 5

Given: A local college student inquires about the use of candles in their dorm room. Candles:

Options:

A.

may not be used.

B.

may be used in a sprinklered dormitory.

C.

must be kept a minimum 12 in. from combustibles.

D.

must be kept a minimum 36 in. from combustibles.

Question 6

When investigating a complaint of a violation within an occupied public area, the fire inspector:

Options:

A.

must give prior notice to the occupant.

B.

need not give prior notice of the inspection to the occupant.

C.

must provide the occupant with at least 24 hours of advance notice.

D.

must either give prior notice to the occupant or obtain an inspection warrant.

Question 7

A building occupied for aerosol storage shall be classified as which of the following occupancy classifications?

Options:

A.

High-hazard Group H

B.

High-hazard Group H-2

C.

High-hazard Group H-3

D.

Group S-1

Question 8

Exit signs shall have words on the sign in letters ___ inches in height.

Options:

A.

three

B.

four

C.

five

D.

six

Question 9

Incineration operations must comply with which of the following requirements?

Options:

A.

Operators must be at least 21 years of age

B.

Incineration which creates an odor when burning requires a fire permit

C.

Fuel-fired incinerators must be preheated for at least 20 minutes before use

D.

Incineration operations must stop if the fire code official determines that the odor is offensive to nearby residents

Question 10

Extra-high-rack combustible storage is defined in the fire code as any storage on racks of Class I, II, III, or IV commodities which exceed ___ ft. in height, and any storage on racks of high-hazard commodities which exceed ___ ft. in height.

Options:

A.

20; 30

B.

30; 40

C.

40; 30

D.

50; 40

Question 11

Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:

Options:

A.

at least 4 ft. wide.

B.

built of noncombustible construction.

C.

built of nonferrous, nonsparking metal.

D.

located no closer than 3 ft. to the side of the tank.

Question 12

Quantities of flammable liquid storage in a control area of an Industrial Occupancy may be doubled when:

Options:

A.

permission is granted by the chief.

B.

the control area exceeds 50,000 sq. ft.

C.

the building is protected with automatic sprinklers.

D.

the control area is provided with exhaust ventilation in accordance with fire code requirements.

Question 13

A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?

Options:

A.

1

B.

2

C.

3

D.

4

Question 14

In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

Options:

A.

5

B.

10

C.

20

D.

30

Question 15

Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:

Options:

A.

permission is granted by the chief.

B.

the control area exceeds 50,000 sq. ft.

C.

the building is protected with automatic sprinklers.

D.

the control area is provided with exhaust ventilation in accordance with fire code requirements.

Question 16

Fire inspectors receiving citizen complaints about a building should first:

Options:

A.

record all pertinent information.

B.

investigate the history of the building.

C.

forward the complaint to the senior inspector.

D.

inform the owner of the building that a complaint has been filed against him.

Question 17

A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds

Options:

A.

225

B.

500

C.

1,000

D.

2,500

Question 18

An acceptance test for a fire alarm system in a new apartment building should be scheduled after:

Options:

A.

each zone is completed.

B.

the contractor verifies full compliance.

C.

the hydrostatic test of the underground main is completed.

D.

the system has been installed and operating for one year.

Question 19

A Type I handrail that is not circular shall have a minimum perimeter dimension of ___ inches.

Options:

A.

1.25

B.

2

C.

4

D.

6.25

Question 20

Where requirements for fire safety are not specifically provided for by the International Fire Code, which of the following shall have the responsibility to determine the applicable requirements?

Options:

A.

City manager.

B.

Legal counsel.

C.

Board of appeals.

D.

Fire code official.

Question 21

Given: In automobile refinishing spray booths where drying by heat is done in the spray booth, the spray booth shall be equipped with interlocks between the spraying and drying apparatus and the ventilating system.

These interlocks shall be arranged to purge the spray vapors from the spray booth for a minimum period of __ minutes before the drying apparatus can be operated.

Options:

A.

2

B.

3

C.

4

D.

5

Question 22

Which of the following situations requires securing of an operational permit from the code official prior to commencing the related activity?

Options:

A.

Storing 85,000 bd. ft. of lumber.

B.

Inside storage of 100 cu. ft. of baled cotton.

C.

Fruit ripening operations using carbon dioxide gas.

D.

Organic coating production facility producing 2 gallons per day.

Question 23

One or more approved fire extinguishers must be located within __ ft. of hot work locations.

Options:

A.

20

B.

30

C.

40

D.

50

Question 24

Keys necessary for the unlocking of exit doors must be individually identifiable by both sight and touch in which of the following occupancies?

Options:

A.

Group A occupancies

B.

Group E occupancies

C.

Group I occupancies

D.

Group R occupancies

Question 25

A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.

Options:

A.

hazardous materials

B.

flammable liquids only

C.

combustible liquids only

D.

corrosive materials only

Question 26

Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.

Options:

A.

55

B.

100

C.

250

D.

500